Biot to Kiloampere

Bi

1 Bi

kA

0.01 kA

Conversion History

ConversionReuseDelete

1 Bi (Biot) → 0.01 kA (Kiloampere)

Just now

Entries per page:

1–1 of 1


Quick Reference Table (Biot to Kiloampere)

Biot (Bi)Kiloampere (kA)
0.10.001
0.50.005
10.01
50.05
100.1
300.3
1001

About Biot (Bi)

The biot (Bi) equals exactly 10 amperes and is the base unit of electric current in the centimeter-gram-second electromagnetic (CGS-EMU) system. It is defined as the current in a pair of parallel conductors 1 cm apart that produces a force of 2 dynes per centimeter length — the CGS-EMU analogue of the SI ampere definition. In the CGS-EMU system the biot plays the same foundational role the ampere plays in SI: all other electromagnetic CGS-EMU units are derived from it. The biot is essentially obsolete in modern practice, but it appears in older physics literature and classical electrodynamics textbooks alongside the dyne, gauss, and oersted.

A current of 1 Bi equals 10 A — roughly the draw of a domestic electric kettle. References to the biot appear primarily in historical or theoretical contexts, not modern instrumentation.

Etymology: Named after Jean-Baptiste Biot (1774–1862), French physicist who, with Félix Savart, established the Biot–Savart law describing the magnetic field generated by a steady electric current.

About Kiloampere (kA)

The kiloampere (kA) equals one thousand amperes and appears where extremely high currents are generated or measured. A typical lightning bolt carries a peak current of 20–30 kA, though extreme strokes can exceed 200 kA. Industrial arc furnaces melting steel draw 50–100 kA through graphite electrodes. Aluminum electrolysis cells in smelters operate at 150–500 kA of continuous DC current per pot. Rail electromagnetic launchers pulse at hundreds of kiloamperes. Resistance spot welding uses 5–30 kA pulses lasting milliseconds to join metal sheets.

A typical lightning bolt peaks at 20–30 kA. Aluminum smelting cells run continuously at 150–300 kA of electrolysis current.


Biot – Frequently Asked Questions

The CGS-EMU system defines its base units using centimeters, grams, and seconds instead of meters, kilograms, and seconds. The factor of 10 falls out naturally from the dimensional conversion: 1 Bi produces 2 dyn/cm force between wires 1 cm apart, and working through the CGS-to-SI conversion yields exactly 10 A.

Biot was a French physicist (1774–1862) who co-discovered the Biot–Savart law in 1820, describing how electric current generates a magnetic field in space. This was one of the foundational results linking electricity to magnetism. The CGS community honored him by naming their electromagnetic current unit after him.

Essentially no. Even theorists who prefer CGS units typically use Gaussian units rather than pure CGS-EMU. The biot appears mainly in textbook conversion tables, historical physics papers, and graduate-level electrodynamics courses that teach multiple unit systems for pedagogical reasons.

Multiply biots by 10 to get amperes; divide amperes by 10 to get biots. A 30 A circuit carries 3 Bi; a 0.5 Bi current is 5 A. It is one of the simplest unit conversions in physics — just move the decimal point one place.

The Biot-Savart law calculates the magnetic field produced by a small segment of current-carrying wire at any point in space. In CGS-EMU, it uses biots for current and gauss for the field. In SI it uses amperes and teslas. The law itself is fundamental — it is used to design MRI magnets, motors, and particle accelerators.

Kiloampere – Frequently Asked Questions

A spot welder uses a large step-down transformer: high voltage at low current on the primary becomes very low voltage (1–2 V) at enormous current (5–30 kA) on the secondary. The copper electrode tips concentrate this current into a small spot, melting the metal in milliseconds. Total power is only 10–60 kW — it is the concentration that does the work.

A typical 14 AWG house wire rated for 15 A would vaporise almost instantly at 1 kA — the I²R heating would melt copper in milliseconds. Industrial busbars carrying kiloamperes are massive rectangular copper or aluminum bars, sometimes water-cooled, with cross-sections of 10–100 cm² to keep current density manageable.

A typical negative cloud-to-ground stroke peaks at 20–30 kA for about 1–2 microseconds. Positive lightning (rarer, about 5% of strikes) can exceed 300 kA. The total charge transferred is only 1–5 coulombs because the pulse is so brief — enormous current, tiny duration.

Aluminum oxide dissolved in molten cryolite at 960 degrees C requires direct electrolytic reduction to separate aluminum metal. Each smelting pot runs at 4–5 V but needs 150–500 kA because the electrochemical reaction requires massive charge transfer. A single smelter may consume 1–2 GW — as much as a small city.

Circuit breakers rated for 10–200 kA interrupting capacity use arc-quenching chambers to extinguish the plasma arc that forms when contacts open under fault current. High-rupture-capacity (HRC) fuses have sand-filled ceramic bodies that absorb the arc energy. Without these devices, a short circuit on a utility feed would weld everything in the panel into slag.

© 2026 TopConverters.com. All rights reserved.