Franklin second to Milliampere

Fr.s

1 Fr.s

mA

0.0000003335641 mA

Conversion History

ConversionReuseDelete

1 Fr.s (Franklin second) → 3.335641e-7 mA (Milliampere)

Just now

Entries per page:

1–1 of 1


Quick Reference Table (Franklin second to Milliampere)

Franklin second (Fr.s)Milliampere (mA)
10.0000003335641
100.000003335641
1000.00003335641
1,000,0000.3335641
1,000,000,000333.5641
3,000,000,0001,000.6923

About Franklin second (Fr.s)

The franklin per second (Fr/s) equals approximately 3.335641×10⁻¹⁰ amperes. The franklin (Fr), also called the statcoulomb, is the CGS-ESU unit of electric charge; one franklin per second of charge flow constitutes one statampere of current. The conversion factor arises from c/10 in CGS (where c ≈ 3×10¹⁰ cm/s), linking the ESU and SI charge systems. The franklin itself honors Benjamin Franklin, whose experiments established the convention of positive and negative electric charge. The unit appears in older electrostatics and radiation dosimetry literature and is otherwise of historical interest only.

1 Fr/s ≈ 3.336×10⁻¹⁰ A. One ampere of current corresponds to approximately 3×10⁹ franklin per second.

About Milliampere (mA)

The milliampere (mA) equals one thousandth of an ampere (10⁻³ A) and is the practical unit for most consumer electronics and lighting circuits. USB 2.0 ports supply up to 500 mA; USB-C Power Delivery can reach 5,000 mA (5 A). A standard 5 mm indicator LED operates at 10–20 mA; mid-power LED drivers supply 100–350 mA. Human perception of electric shock begins near 1 mA; currents above 10 mA cause involuntary muscle contraction, and above 100 mA can be lethal. Wireless sensors, earphones, and small motors typically draw single-digit to low-hundreds of milliamperes.

A USB 2.0 port provides up to 500 mA for charging. A standard 5 mm indicator LED operates at around 20 mA.


Franklin second – Frequently Asked Questions

Franklin (1706–1790) was the American polymath who proved lightning is electrical with his famous kite experiment in 1752. He introduced the convention of "positive" and "negative" charge that we still use today. He arbitrarily assigned positive to the charge on glass rubbed with silk — which turned out to be a deficit of electrons, giving us the unfortunate convention that current flows opposite to electron motion.

The roentgen (R) was defined in 1928 as the radiation exposure producing 1 ESU of charge (1 franklin ≈ 3.336 × 10⁻¹⁰ C) per cm³ of dry air at STP. This CGS-era definition stuck because radiation safety regulations were already built around it. Even though the SI gray replaced the roentgen for dosimetry, the roentgen — and its franklin-based definition — persists in US regulatory and medical imaging contexts.

The legacy unit of radiation exposure, the roentgen (R), is defined as the amount of X-ray or gamma radiation that produces 1 esu of charge (1 franklin) per cubic centimeter of dry air at STP. This definition dates from the 1920s when CGS-ESU was standard. Modern dosimetry uses grays and sieverts, but the roentgen and its franklin-based definition persist in some medical and regulatory contexts.

One Fr/s is about 0.33 nanoamperes — less current than a sleeping microcontroller draws. To equal the 1 A flowing through a phone charger cable, you would need about 3 billion franklins per second. The unit is spectacularly impractical for anything beyond electrostatics calculations.

Sort of. He labelled the charge on glass rubbed with silk as "positive," not knowing it was caused by removing electrons. When Thomson discovered the electron in 1897, it turned out electrons carry what Franklin called negative charge. So conventional current flows from + to −, opposite to actual electron flow. Engineers and physicists have lived with this "mistake" for over 250 years.

Milliampere – Frequently Asked Questions

The danger thresholds for 50/60 Hz AC are roughly: 1 mA (tingling), 10–20 mA (muscle lock — you cannot let go), 75–100 mA (ventricular fibrillation), and 200+ mA (cardiac arrest and burns). DC is somewhat less dangerous at the same current. Duration matters enormously — 100 mA for 1 second is more lethal than 100 mA for 10 ms.

Battery capacity is rated in milliampere-hours (mAh), not milliamps. A 4,000 mAh battery holds 4,000 mA for one hour (or 2,000 mA for two hours). The charger delivers 2 A (2,000 mA) of current, and it takes about 2 hours to fill that 4,000 mAh battery from empty.

A wireless earbud draws 5–15 mA during playback. A TV remote uses about 10 mA when pressing a button. An LED nightlight consumes 20–50 mA. A smoke detector in standby draws 10–30 μA (0.01–0.03 mA) — so low it runs on a 9V battery for years.

Standard 5 mm indicator LEDs were designed around a 20 mA operating point — bright enough to see clearly, low enough to avoid overheating the tiny die. All datasheet specs (luminous intensity, color, forward voltage) are measured at this "test current." High-power LEDs use 350 mA or 700 mA as their reference instead.

Milliamp-hours measure charge capacity; milliamps measure current flow rate. A 2,000 mAh battery can deliver 2,000 mA for 1 hour, or 200 mA for 10 hours, or 20 mA for 100 hours — current times time equals capacity. Dividing mAh by mA gives approximate runtime in hours.