Calories (th)/second to BTU/hour
cal(th)/s
BTU/h
Conversion History
| Conversion | Reuse | Delete |
|---|---|---|
| No conversion history to show. | ||
Quick Reference Table (Calories (th)/second to BTU/hour)
| Calories (th)/second (cal(th)/s) | BTU/hour (BTU/h) |
|---|---|
| 0.1 | 1.427640059300702754 |
| 1 | 14.27640059300702754 |
| 10 | 142.76400593007027540001 |
| 14.3 | 204.15252848000049382202 |
| 100 | 1,427.64005930070275400011 |
| 1,000 | 14,276.40059300702754000108 |
| 10,000 | 142,764.00593007027540001085 |
About Calories (th)/second (cal(th)/s)
Calories (thermochemical) per second (cal(th)/s) equals 4.184 watts. It is a caloric power unit used in thermochemistry and laboratory heat-flow measurements where energy is expressed in thermochemical calories rather than joules. Reaction calorimeters and bomb calorimeters sometimes report heat release rates in this unit. It is closely related to the watt but retains the calorie convention of chemistry rather than physics.
A 60 W light bulb dissipates about 14.3 cal(th)/s as heat. A vigorous chemical reaction releasing 100 cal(th)/s generates 418 W of thermal power.
About BTU/hour (BTU/h)
BTU per hour (BTU/h) is the standard power unit for heating and cooling equipment in the United States — air conditioners, furnaces, heat pumps, and water heaters are all rated in BTU/hour. One BTU/h equals approximately 0.293 watts. A typical window air conditioner is rated at 5,000–24,000 BTU/h; a central HVAC system for a mid-sized home at 36,000–60,000 BTU/h (called "3 to 5 tons"). The unit appears exclusively in US thermal and HVAC engineering.
A 12,000 BTU/h (1-ton) air conditioner uses roughly 1,200 W of electricity while removing 3,517 W of heat from the room. A typical US gas furnace is rated 60,000–100,000 BTU/h.
Calories (th)/second – Frequently Asked Questions
Why do chemists use calories per second instead of watts?
Tradition and unit consistency. When your energy measurements are in calories (specific heat of water = 1 cal/g/°C makes calculations beautifully clean), expressing rates in cal/s keeps everything in the same system. A chemist measuring how fast a reaction heats 500 mL of water doesn't want to convert to joules just to report a rate. The calorie makes water-based calorimetry arithmetic almost trivial.
What is the difference between a calorie and a Calorie in this context?
The thermochemical calorie (lowercase "c") used in cal/s equals 4.184 joules. The food Calorie (uppercase "C" or kilocalorie) is 1,000× larger at 4,184 joules. So 1 food Calorie/s = 4,184 watts — roughly the power of a space heater. Nutrition labels use kilocalories but write "Calories" with a capital C, creating one of the most persistent unit confusions in science. When you see cal/s in chemistry, it's always the small calorie.
How many cal/s does an exothermic chemical reaction typically release?
It varies enormously. Neutralizing a strong acid with a strong base might release 0.5–5 cal/s in a teaching lab. Combustion of magnesium ribbon produces 50–200 cal/s of intense white-hot heat. Thermite reactions can exceed 10,000 cal/s (42 kW). Explosive decomposition of TNT releases energy at roughly 250,000 cal/s (1 MW) during detonation. The rate depends on both the enthalpy change and how fast the reaction proceeds.
How do you measure heat output in calories per second experimentally?
A reaction calorimeter submerges the reaction vessel in a known mass of water and measures temperature rise over time. If 1,000 g of water rises 0.5°C in 10 seconds, the heat release is 500 cal in 10 seconds = 50 cal/s. Modern isothermal calorimeters use Peltier elements to maintain constant temperature, measuring the electrical power needed to compensate — giving cal/s readings with milliwatt precision.
Is the thermochemical calorie still used in modern research?
Increasingly rarely. IUPAC officially recommends joules, and most modern journals require SI units. However, the calorie persists in biochemistry (metabolic rates), nutrition (food energy), and some physical chemistry subfields where decades of reference data are in calories. Older researchers and textbooks still think in calories. The 4.184 conversion factor is burned into every chemist's brain, even if they wish it weren't.
BTU/hour – Frequently Asked Questions
How many BTU/h air conditioner do I need for my room?
The classic rule: 20 BTU/h per square foot. A 300 sq ft bedroom needs about 6,000 BTU/h; a 500 sq ft living room about 10,000 BTU/h. But this varies wildly with sun exposure (+10% for south-facing), ceiling height, insulation quality, number of occupants (+600 BTU per person), and climate zone. A room above a pizza oven in Phoenix needs more than a basement in Seattle. When in doubt, oversize slightly — an undersized unit runs constantly and never reaches setpoint.
What happens if you oversize or undersize your home AC unit by a ton?
Undersizing is obvious — the unit runs constantly and never reaches the thermostat setpoint on hot days. But oversizing is worse in subtle ways. An oversized AC cools the air quickly then shuts off before removing enough humidity, leaving you with a clammy 72°F house. The short cycles also wear the compressor faster (startup is the hardest moment) and waste energy. A 1-ton oversize in a humid climate like Florida can raise indoor humidity from a comfortable 45% to a muggy 60%. Proper Manual J load calculations matter more than most homeowners realize.
What does "1 ton" of air conditioning mean in BTU/h?
Exactly 12,000 BTU/h. One ton of AC is the cooling effect of melting one short ton (2,000 lbs) of ice over 24 hours. The ice absorbs 288,000 BTU of heat as it melts (2,000 lbs × 144 BTU/lb latent heat), divided by 24 hours = 12,000 BTU/h. Residential systems run 1.5–5 tons; commercial buildings 10–500 tons. The "ton" unit persists because HVAC contractors think in tons — "that house needs a 3-ton unit" is faster than "that house needs 10.5 kW of cooling."
How efficient is a modern air conditioner in BTU/h per watt?
Modern units achieve 12–25 BTU/h per watt of electricity (SEER 12–25). A SEER 20 unit removes 20 BTU/h of heat for every watt consumed — effectively a 3:1 heat pump ratio. That 12,000 BTU/h window unit draws 500–1,000 W of electricity depending on efficiency. The best mini-splits achieve SEER 30+, removing 30 BTU/h per watt, making them cheaper to run than resistive electric heaters even in heating mode.
How do BTU/h ratings differ between gas furnaces and heat pumps?
A gas furnace's BTU/h rating is its thermal output after combustion efficiency losses (typically 80–96% of fuel input). A heat pump's BTU/h rating is the heat delivered including energy moved from outside — at COP 3, a heat pump delivering 36,000 BTU/h uses only 12,000 BTU/h worth of electricity. This makes direct BTU/h comparisons misleading: a 60,000 BTU/h furnace and a 60,000 BTU/h heat pump deliver the same heat, but the heat pump uses one-third the energy.