About Horsepower (Electric) (hp)

Electric horsepower (hp(E)) is defined as exactly 746 watts — a rounded value used in the US for rating electric motors. It is the standard on US electric motor nameplates, pump ratings, and industrial motor specifications. The electric hp is marginally larger than the metric hp (735.5 W) and essentially identical to the mechanical and international hp (745.7 W). When purchasing a motor in the US, the hp rating refers to this electric horsepower definition.

A 1 hp electric motor draws about 746 W of shaft output power (actual electrical draw is higher due to efficiency losses). US pool pumps are typically rated 0.75–2 hp (electric).

About BTU/second (BTU/s)

BTU per second (BTU/s) is a high-power thermal unit equal to approximately 1,055 watts. It is used in large-scale industrial heating, combustion engineering, and power plant heat rate analysis where BTU is the preferred energy unit and the timescale is seconds. One BTU/s is roughly the power of a small domestic gas boiler running continuously. The unit bridges the BTU-based thermal engineering tradition with second-based rate measurement.

A large industrial gas burner rated at 5 BTU/s delivers about 5,275 W of thermal power. A 1 BTU/s heat source could raise 1 lb of water by 1 °F every second.


Horsepower (Electric) – Frequently Asked Questions

It's a deliberate rounding for simplicity. The mechanical horsepower is 745.69987... watts — an ugly number for electrical calculations. The electric motor industry rounded to 746 W for clean nameplate ratings and straightforward calculations. The 0.04% difference is far below any motor's manufacturing tolerance. Some standards even use 750 W as an approximation. In practice, the distinction between 745.7 and 746 matters only to standards lawyers and unit conversion pedants.

Divide the hp rating by the motor efficiency and power factor. A 5 hp motor at 90% efficiency draws: 5 × 746 / 0.90 = 4,144 W of electrical power to deliver 3,730 W of shaft power. For three-phase motors, also divide by (√3 × voltage × power factor) to get amperage. Real-world efficiency ranges from 75% for small motors to 96% for large premium-efficiency ones. The nameplate always shows shaft output, not electrical input — a common source of confusion.

Because American homeowners and pool contractors have decades of experience sizing pumps in hp: "a 20,000-gallon pool needs a 1.5 hp pump" is ingrained knowledge. The Department of Energy actually mandated variable-speed pool pumps in 2021 and encouraged watt-based efficiency ratings, but manufacturers still prominently display hp because it drives purchasing decisions. A customer choosing between a 1 hp and 1.5 hp pump understands the difference intuitively; 746 W vs 1,119 W means nothing to them.

NEMA (National Electrical Manufacturers Association) defines standard motor sizes using electric hp: 1/4, 1/3, 1/2, 3/4, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100 hp and up. These are standardized frame sizes — a 5 hp motor from any manufacturer fits the same mounting bolts. The hp(E) rating is the shaft output; NEMA also specifies efficiency classes (IE1 through IE4) that determine how much electrical power the motor actually consumes.

Not usually. EV manufacturers rate motors in kilowatts because the electrical connection is obvious and kW is internationally understood. A Tesla Model 3 motor is listed as 211 kW, not "283 hp(E)." However, marketing materials often convert to hp for American consumers: "283 horsepower" sounds sportier. Interestingly, EV motors are far more efficient (90–97%) than combustion engines (25–40%), so a 200 hp EV motor consumes far less total energy than a 200 hp gasoline engine.

BTU/second – Frequently Asked Questions

In US combustion engineering and power plant heat rate analysis, fuel energy content is natively specified in BTU (natural gas is sold per therm = 100,000 BTU). Expressing burner output in BTU/s keeps the calculation in one unit system, avoiding constant conversions. When your fuel flow is in BTU/min and your efficiency calculations use BTU, switching to watts mid-calculation just creates errors.

One BTU/s ≈ 1,055 watts — roughly a single-bar electric fire or a small hair dryer. It's a surprisingly human-scale unit. A typical US home gas furnace running at full blast produces about 28 BTU/s (100,000 BTU/h ÷ 3,600). A gas stovetop burner on high delivers about 3–5 BTU/s. So BTU/s lands right in the range where you can feel the heat on your face.

Power plant thermal engineering (heat rate analysis), industrial furnace and kiln design, jet engine combustion analysis, and rocket propulsion engineering. NASA specifications for rocket engines often include BTU/s figures. The Space Shuttle Main Engine produced about 12 million BTU/s of thermal power. Steelmaking blast furnaces operate at 50,000–200,000 BTU/s of heat input.

One BTU/s = 1.415 mechanical horsepower, or roughly 1.4 hp. This is useful in automotive and engine testing where dynamometers may report in BTU/s for thermal measurements but engineers think in horsepower. A 400 hp engine rejects about 280 BTU/s through its cooling system at full power (assuming 60% of fuel energy becomes waste heat). The conversion factor is easy to remember: multiply BTU/s by 1.4 to get hp.

A BTU (British Thermal Unit) is the energy needed to raise 1 pound of water by 1°F — about 1,055 joules. Despite the name, Britain abandoned it decades ago. America keeps it because the entire HVAC, natural gas, and building industry infrastructure — codes, equipment ratings, contractor training — is built around BTU. Switching would require rewriting thousands of standards and retraining millions of technicians. It's inertia, pure and simple.