Horsepower (International) to Ton of refrigeration

hp

1 hp

TR

0.21203613 TR

Conversion History

ConversionReuseDelete

1 hp (Horsepower (International)) → 0.21203613 TR (Ton of refrigeration)

Just now · Rounding: Up to 8 significant figures
Recalculate this conversion using your current rounding settings.

Entries per page:

1–1 of 1


Quick Reference Table (Horsepower (International) to Ton of refrigeration)

Horsepower (International) (hp)Ton of refrigeration (TR)
0.50.10601807
10.21203613
102.1203613
10021.203613
20042.407226
40084.814453
1,000212.03613

Results rounded to a maximum of 8 significant figures



About Horsepower (International) (hp)

International mechanical horsepower (hp(I)) is defined as 550 ft·lbf/s using the international foot and standard pound-force, giving exactly 745.69987158227022 watts. It is identical to the British mechanical horsepower selection in this converter. Most US automotive power ratings labelled simply "hp" use mechanical horsepower. It differs from metric hp (PS) by about 1.4% and from electric hp by about 0.04%.

The SAE (Society of Automotive Engineers) uses international horsepower for US automotive ratings. A Ford F-150 5.0L V8 produces 400 hp (international) = 298 kW.

About Ton of refrigeration (TR)

A ton of refrigeration (TR) is defined as exactly 12,000 International Table BTU per hour, BTU(IT)/h. This is exactly 12,660,670.23144 joules per 3,600 seconds, or approximately 3,516.85 watts; the watt value is a nonterminating decimal, not an exact 3,516.85 W factor. Its name comes from the historical cooling effect of a short ton of ice melting over 24 hours. TR is used for commercial and industrial refrigeration and air-conditioning capacity.

A 3-ton residential central air conditioner removes about 10.6 kW of heat from the building. A typical office building chiller might be rated at 200–500 TR.

Etymology: The name originated from cooling with a short ton of ice over 24 hours, using an approximate latent heat of 144 BTU/lb. The converter uses the conventional relationship of exactly 12,000 BTU(IT)/h rather than calculating from a measured latent heat of ice.


Horsepower (International) – Frequently Asked Questions

Mechanical horsepower uses 550 ft·lbf/s, equal to exactly 745.69987158227022 W with the international foot and standard pound-force. Metric horsepower instead uses 75 kgf·m/s, equal to 735.49875 W, while electric horsepower is defined as 746 W. The British and international selections in this converter share the mechanical definition; the labels do not imply different conversion factors.

SAE J1349 specifies measuring net horsepower with all production accessories (alternator, water pump, AC compressor) attached, at standard atmospheric conditions. Before 1972, US manufacturers used gross hp (engine on a test stand with minimal accessories), which inflated numbers by 15–25%. The switch to SAE net ratings famously caused "overnight" power drops: a Corvette went from "350 hp" (gross) to "255 hp" (net) in 1972 — same engine, honest measurement.

Japan officially uses metric PS (called 馬力, "horse power," abbreviated PS after the German). Japanese car specs list PS, and JIS standards define power in PS. However, for international export, Japanese manufacturers convert to international hp or kW depending on the destination market. A Nissan GT-R produces 570 PS for the Japanese market and 565 hp for the US market — the same engine, different unit systems, and the ~1% gap occasionally causes forum arguments.

The Wärtsilä-Sulzer RTA96-C, a marine diesel engine used in the largest container ships, produces about 109,000 hp (international) — 80,080 kW from 14 cylinders each the size of a small apartment. It's 13.5 meters tall and weighs 2,300 tonnes. At 102 RPM, it turns propellers the size of houses. For comparison, a Saturn V rocket's five F-1 engines produced about 217 million hp combined, but only for 2.5 minutes.

Probably, but slowly. The EU already legally requires kW; China uses kW; scientific and engineering communities prefer kW. But cultural inertia is powerful — Americans have been buying cars by horsepower for over a century, and "how many horses under the hood" is deeply embedded in car culture. The transition to EVs may accelerate the shift, since electric motors are naturally rated in kW. Give it 20–30 years, and hp may join the furlong and the gill in the museum of obsolete units.

Ton of refrigeration – Frequently Asked Questions

Before mechanical refrigeration, buildings were literally cooled with ice. A "ton of refrigeration" was the cooling you got from melting one ton of ice per day. When compressor-based AC arrived in the early 1900s, the ice-based unit stuck because the entire industry — contractors, building codes, ductwork sizing — was built around it. Telling a building owner "you need 200 tons of cooling" was intuitive when they used to order 200 tons of ice. The unit survived because switching costs exceed inconvenience costs.

Roughly 1 ton per 400–600 sq ft of office space, depending on climate, occupancy, glazing, and internal heat loads (computers, lights, people). A 50,000 sq ft office needs 80–125 tons. Data centers are extreme: they need 1 ton per 200–300 sq ft because of server heat. A single rack of GPU servers can require 5–10 tons of cooling alone. The Trump Tower in New York has about 2,600 tons of installed cooling capacity.

When outdoor temperatures exceed 45°C for months, every building runs AC at maximum capacity simultaneously — there is no "shoulder season." Dubai alone has over 1.5 million tons of district cooling capacity. These plants chill water at a central facility and pipe it underground to hundreds of buildings, achieving 40–50% better efficiency than individual rooftop units. The Pearl-Qatar plant in Doha runs 130,000 tons — cooling an entire artificial island. Without district cooling, the electrical grid in Gulf states would need to be 30–40% larger just to handle dispersed AC compressors.

The district cooling plant at The Pearl-Qatar in Doha has about 130,000 tons of refrigeration capacity — enough to cool a small city in one of the world's hottest climates. Dubai's district cooling network exceeds 1.5 million tons total across multiple plants. For a single building, the Venetian Macao resort has roughly 16,000 tons. These megascale systems use chilled water loops distributing cooling across kilometers of underground pipes.

A typical 40,000 sq ft supermarket needs 80–150 tons: roughly 40–60 tons for the sales floor AC, and another 40–90 tons for refrigerated cases, walk-in coolers, and freezers. The frozen food aisle alone can require 20–30 tons. Open-top refrigerated cases are notoriously wasteful — they dump cold air into the store, which the AC must then remove. Modern stores with glass-doored cases can cut refrigeration load by 30–40%.