Microampere to Biot
μA
Bi
Conversion History
| Conversion | Reuse | Delete |
|---|---|---|
1 μA (Microampere) → 0.0000001 Bi (Biot) Just now · Rounding: Up to 8 significant figures | Recalculate this conversion using your current rounding settings. |
Quick Reference Table (Microampere to Biot)
| Microampere (μA) | Biot (Bi) |
|---|---|
| 1 | 0.0000001 |
| 10 | 0.000001 |
| 50 | 0.000005 |
| 100 | 0.00001 |
| 500 | 0.00005 |
| 1,000 | 0.0001 |
Results rounded to a maximum of 8 significant figures
About Microampere (μA)
The microampere (μA) equals one millionth of an ampere (10⁻⁶ A) and is the standard unit for quiescent and standby currents in battery-powered electronics. Operational amplifier input bias currents, photodiode outputs under dim light, and EEG scalp electrode signals all fall in the microampere range. Many modern microcontrollers in low-power run mode consume under 100 μA, enabling coin-cell operation for months. Analytical instruments such as pH meters and reference electrodes operate at microampere levels to avoid disturbing the solution being measured. Implantable cardiac pacemakers deliver stimulation pulses of several hundred microamperes.
A cardiac pacemaker delivers stimulation pulses of roughly 100–500 μA. A modern ARM microcontroller in active low-power mode draws around 50–200 μA.
About Biot (Bi)
The biot (Bi) is the base unit of electric current in the centimeter-gram-second electromagnetic (CGS-EMU) system. Under the traditional pre-2019 CGS-to-SI mapping retained by this converter, one biot corresponds to 10 amperes. It is defined as the current in a pair of parallel conductors 1 cm apart that produces a force of 2 dynes per centimeter length — the CGS-EMU analogue of the former force-based SI ampere definition. The biot, EMU of current, and CGS e.m. unit are exactly the same current unit within CGS-EMU. Their 10 A relationship is a historical conversion convention rather than an exact physical conversion to the post-2019 SI, in which vacuum permeability is experimentally determined. The biot is essentially obsolete in modern practice, but it appears in older physics literature and classical electrodynamics textbooks alongside the dyne, gauss, and oersted.
Under the traditional mapping used here, 1 Bi corresponds to 10 A — roughly the draw of a domestic electric kettle. References to the biot appear primarily in historical or theoretical contexts, not modern instrumentation.
Etymology: Named after Jean-Baptiste Biot (1774–1862), French physicist who, with Félix Savart, established the Biot–Savart law describing the magnetic field generated by a steady electric current.
Microampere – Frequently Asked Questions
How long can a coin cell battery last at microampere currents?
A CR2032 coin cell has about 225 mAh capacity. At 10 μA continuous draw, it lasts roughly 225,000 / 10 = 22,500 hours — about 2.5 years. At 1 μA, theoretical life exceeds 25 years, though self-discharge limits practical life to about 10 years.
Can microampere currents be dangerous to humans?
Not from shock — the perception threshold is about 500 μA (0.5 mA) for DC and 1,000 μA for AC at 60 Hz. However, microampere currents applied directly to the heart (e.g., through a catheter) can cause ventricular fibrillation at as little as 50–100 μA, which is why medical device safety standards are so strict.
Why do pH meters need to operate at microampere levels?
A glass pH electrode has an internal resistance of 10–1,000 megaohms. Drawing more than a few microamperes would cause voltage drops across this resistance, shifting the reading. Modern pH meters use high-input-impedance amplifiers that draw under 1 μA to avoid disturbing the electrochemical potential being measured.
What is quiescent current and why is it measured in microamperes?
Quiescent current (Iq) is what an IC draws when powered on but doing nothing — no signal processing, no load driving. For battery-powered designs, low Iq is critical. A voltage regulator with 1 μA Iq wastes far less standby power than one with 100 μA, directly extending battery life in always-on devices.
How does a pacemaker deliver just a few hundred microamperes so precisely?
Pacemakers use constant-current output stages that regulate pulse amplitude to within ±5 μA. The pulse is typically 100–500 μA for 0.4–1.5 ms, just enough to depolarise heart tissue and trigger a contraction. Modern devices automatically adjust the current to the minimum needed, conserving the battery for its 8–12 year design life.
Biot – Frequently Asked Questions
Why does this converter map one biot to 10 amperes?
The CGS-EMU system defines its base units using centimeters, grams, and seconds instead of meters, kilograms, and seconds. Under the former force-based SI ampere definition, converting the force between parallel currents made 1 Bi exactly 10 A. Since the 2019 SI redefinition, vacuum permeability is experimentally determined, so this converter retains 10 A as the stable traditional CGS-to-SI reference mapping rather than presenting it as an exact modern physical conversion.
Who was Jean-Baptiste Biot and why does he have a current unit?
Biot was a French physicist (1774–1862) who co-discovered the Biot–Savart law in 1820, describing how electric current generates a magnetic field in space. This was one of the foundational results linking electricity to magnetism. The CGS community honored him by naming their electromagnetic current unit after him.
Does anyone still use the biot in modern physics?
Essentially no. Even theorists who prefer CGS units typically use Gaussian units rather than pure CGS-EMU. The biot appears mainly in textbook conversion tables, historical physics papers, and graduate-level electrodynamics courses that teach multiple unit systems for pedagogical reasons.
How do I convert between biots and amperes?
Multiply biots by 10 to get amperes; divide amperes by 10 to get biots. A 30 A circuit carries 3 Bi; a 0.5 Bi current is 5 A. It is one of the simplest unit conversions in physics — just move the decimal point one place.
What is the Biot-Savart law and how does it relate to the biot unit?
The Biot-Savart law calculates the magnetic field produced by a small segment of current-carrying wire at any point in space. In CGS-EMU, it uses biots for current and gauss for the field. In SI it uses amperes and teslas. The law itself is fundamental — it is used to design MRI magnets, motors, and particle accelerators.