CGS e.m. unit to Biot

CGS EMU

1 CGS EMU

Bi

1 Bi

Conversion History

ConversionReuseDelete

1 CGS EMU (CGS e.m. unit) → 1 Bi (Biot)

Just now · Rounding: Up to 8 significant figures
Recalculate this conversion using your current rounding settings.

Entries per page:

1–1 of 1


Quick Reference Table (CGS e.m. unit to Biot)

CGS e.m. unit (CGS EMU)Biot (Bi)
0.10.1
0.50.5
11
55
1010
3030
100100

Results rounded to a maximum of 8 significant figures



About CGS e.m. unit (CGS EMU)

The CGS electromagnetic unit (CGS e.m. unit) of current is exactly identical to the biot and the EMU of current — all three are names for the same quantity within the CGS-EMU system. Under the traditional pre-2019 CGS-to-SI mapping retained by this converter, one CGS e.m. unit corresponds to 10 amperes; that relationship is conventional rather than an exact physical conversion to the post-2019 SI. The term "CGS e.m. unit" is used explicitly when distinguishing the electromagnetic subsystem from the electrostatic (ESU) or Gaussian subsystems within CGS. In the CGS-EMU framework, resistance, capacitance, and inductance take unfamiliar dimensions compared to SI; the system is now of historical and theoretical interest only. Modern engineering and science universally use SI.

Under the traditional mapping used here, 1 CGS e.m. unit corresponds to 10 A. A 100 A industrial busbar corresponds to 10 CGS e.m. units. The designation appears only in pre-1960 electrical engineering literature.

About Biot (Bi)

The biot (Bi) is the base unit of electric current in the centimeter-gram-second electromagnetic (CGS-EMU) system. Under the traditional pre-2019 CGS-to-SI mapping retained by this converter, one biot corresponds to 10 amperes. It is defined as the current in a pair of parallel conductors 1 cm apart that produces a force of 2 dynes per centimeter length — the CGS-EMU analogue of the former force-based SI ampere definition. The biot, EMU of current, and CGS e.m. unit are exactly the same current unit within CGS-EMU. Their 10 A relationship is a historical conversion convention rather than an exact physical conversion to the post-2019 SI, in which vacuum permeability is experimentally determined. The biot is essentially obsolete in modern practice, but it appears in older physics literature and classical electrodynamics textbooks alongside the dyne, gauss, and oersted.

Under the traditional mapping used here, 1 Bi corresponds to 10 A — roughly the draw of a domestic electric kettle. References to the biot appear primarily in historical or theoretical contexts, not modern instrumentation.

Etymology: Named after Jean-Baptiste Biot (1774–1862), French physicist who, with Félix Savart, established the Biot–Savart law describing the magnetic field generated by a steady electric current.


CGS e.m. unit – Frequently Asked Questions

The CGS e.m. unit of current (10 A) was inconveniently large for everyday lab work, while the CGS e.m. unit of resistance (the abohm, 10⁻⁹ Ω) was absurdly small. Physicists created "practical" units — the ampere, volt, and ohm — as decimal multiples that gave human-scale numbers. The ampere was set at 0.1 abampere. These practical units eventually became SI, while the "absolute" CGS units became historical footnotes.

In the 19th century, electricity and magnetism were treated as partially separate phenomena, leading to separate "natural" unit choices. The EMU system normalized magnetic permeability to 1; the ESU system normalized electric permittivity to 1; the Gaussian system mixed both. Once Maxwell unified electromagnetism, this fragmentation became unnecessary — but the systems persisted in literature for a century.

They introduced "practical" units — the ampere, volt, and ohm — as decimal multiples of CGS-EMU quantities. The ampere was defined as 0.1 abampere (CGS e.m. unit). This practical system eventually became SI, while the "absolute" CGS units faded. The factor of 10 was chosen for human-scale convenience.

The gauss (magnetic flux density, = 10⁻⁴ tesla) remains surprisingly common — refrigerator magnets are rated in gauss, and MRI field strengths are often quoted in both tesla and gauss. The oersted (magnetic field strength) appears in materials science. These CGS-EMU holdouts persist because their numerical values are more convenient for everyday magnets.

The SI was officially adopted in 1960, but the transition took decades. Most physics journals required SI by the 1970s, though astrophysics and plasma physics held onto Gaussian CGS into the 2000s. Some subfields never fully switched — you can still find new papers using gauss and oersted alongside tesla and A/m.

Biot – Frequently Asked Questions

The CGS-EMU system defines its base units using centimeters, grams, and seconds instead of meters, kilograms, and seconds. Under the former force-based SI ampere definition, converting the force between parallel currents made 1 Bi exactly 10 A. Since the 2019 SI redefinition, vacuum permeability is experimentally determined, so this converter retains 10 A as the stable traditional CGS-to-SI reference mapping rather than presenting it as an exact modern physical conversion.

Biot was a French physicist (1774–1862) who co-discovered the Biot–Savart law in 1820, describing how electric current generates a magnetic field in space. This was one of the foundational results linking electricity to magnetism. The CGS community honored him by naming their electromagnetic current unit after him.

Essentially no. Even theorists who prefer CGS units typically use Gaussian units rather than pure CGS-EMU. The biot appears mainly in textbook conversion tables, historical physics papers, and graduate-level electrodynamics courses that teach multiple unit systems for pedagogical reasons.

Multiply biots by 10 to get amperes; divide amperes by 10 to get biots. A 30 A circuit carries 3 Bi; a 0.5 Bi current is 5 A. It is one of the simplest unit conversions in physics — just move the decimal point one place.

The Biot-Savart law calculates the magnetic field produced by a small segment of current-carrying wire at any point in space. In CGS-EMU, it uses biots for current and gauss for the field. In SI it uses amperes and teslas. The law itself is fundamental — it is used to design MRI magnets, motors, and particle accelerators.

© 2026 TopConverters.com. All rights reserved.