BTU (IT)/minute to BTU (IT)/second

BTU(IT)/min

1 BTU(IT)/min

BTU(IT)/s

0.016666667 BTU(IT)/s

Conversion History

ConversionReuseDelete

1 BTU(IT)/min (BTU (IT)/minute) → 0.016666667 BTU(IT)/s (BTU (IT)/second)

Just now · Rounding: Up to 8 significant figures
Recalculate this conversion using your current rounding settings.

Entries per page:

1–1 of 1


Quick Reference Table (BTU (IT)/minute to BTU (IT)/second)

BTU (IT)/minute (BTU(IT)/min)BTU (IT)/second (BTU(IT)/s)
10.016666667
100.16666667
1001.6666667
5008.3333333
1,00016.666667
5,00083.333333
10,000166.66667

Results rounded to a maximum of 8 significant figures



About BTU (IT)/minute (BTU(IT)/min)

This converter uses International Table BTU per minute, BTU(IT)/min. One BTU(IT)/min transfers exactly 1,055.05585262 joules in 60 seconds, giving approximately 17.58 watts. The conversion uses the exact energy factor and minute duration rather than a separately rounded watt coefficient. Minute-based rates appear in thermal engineering and HVAC commissioning, between second-based measurements and hourly equipment ratings.

A 100,000 BTU/hour furnace (common US home size) delivers about 1,667 BTU/min or roughly 29.3 kW of heat output.

About BTU (IT)/second (BTU(IT)/s)

This converter uses International Table BTU per second, BTU(IT)/s, equal to exactly 1,055.05585262 watts. It represents one BTU(IT) of energy transferred each second, using the same energy definition as the BTU(IT) selection in the energy converter. It is used in industrial heating, combustion engineering, and power plant heat rate analysis where BTU is the preferred energy unit and the timescale is seconds.

A gas burner rated at 5 BTU(IT)/s delivers about 5,275 W of thermal power. This is the heat output, not a statement of electrical input power.


BTU (IT)/minute – Frequently Asked Questions

During commissioning and troubleshooting, when measuring instantaneous heat output over a few minutes. If a furnace is cycling on/off and you're timing its burn cycle, you might measure 2,000 BTU/min during the 8-minute burn phase, then zero during the 4-minute off phase. This gives a clearer picture than the nameplate BTU/h rating, which assumes continuous operation and averages out the cycling.

Multiply by 60. A burner producing 1,500 BTU/min delivers 90,000 BTU/h. Going the other way, divide by 60: a 120,000 BTU/h furnace runs at 2,000 BTU/min when firing. This conversion is so routine in US HVAC work that technicians do it reflexively. The minute rate is more intuitive during short measurements; the hourly rate matches equipment nameplate conventions.

A gas stovetop burner on high: 150–250 BTU/min. A gas fireplace insert: 300–600 BTU/min. A residential water heater recovery: 500–700 BTU/min. A barbecue grill on full: 400–1,000 BTU/min. A clothes dryer: 350–600 BTU/min. These are all common US gas appliances where the original engineering was done in BTU-based units, and the nameplate may show BTU/h but the technician thinks in BTU/min during testing.

A 15 m² (160 sq ft) room in a cold climate needs roughly 100–250 BTU/min (6,000–15,000 BTU/h) of heating depending on insulation quality and outdoor temperature. A portable space heater rated 5,000 BTU/h delivers about 83 BTU/min — adequate for a small well-insulated room but insufficient for a drafty old one. The rule of thumb in US HVAC: 20–30 BTU/h per square foot, or about 0.4 BTU/min per square foot.

Almost never. The rest of the world uses watts or kilowatts for thermal power ratings. Even in countries that once used BTU (like the UK), equipment has long been rated in kW. Some Middle Eastern and Asian HVAC markets use BTU/h because they import US-manufactured equipment with American ratings, but BTU/min specifically is a niche US engineering convention. If you see it, you're almost certainly reading an American document.

BTU (IT)/second – Frequently Asked Questions

In US combustion engineering and power plant heat rate analysis, fuel energy content is natively specified in BTU (natural gas is sold per therm = 100,000 BTU). Expressing burner output in BTU/s keeps the calculation in one unit system, avoiding constant conversions. When your fuel flow is in BTU/min and your efficiency calculations use BTU, switching to watts mid-calculation just creates errors.

One BTU/s ≈ 1,055 watts — roughly a single-bar electric fire or a small hair dryer. It's a surprisingly human-scale unit. A typical US home gas furnace running at full blast produces about 28 BTU/s (100,000 BTU/h ÷ 3,600). A gas stovetop burner on high delivers about 3–5 BTU/s. So BTU/s lands right in the range where you can feel the heat on your face.

Power plant thermal engineering (heat rate analysis), industrial furnace and kiln design, jet engine combustion analysis, and rocket propulsion engineering. NASA specifications for rocket engines often include BTU/s figures. The Space Shuttle Main Engine produced about 12 million BTU/s of thermal power. Steelmaking blast furnaces operate at 50,000–200,000 BTU/s of heat input.

One BTU/s = 1.415 mechanical horsepower, or roughly 1.4 hp. This is useful in automotive and engine testing where dynamometers may report in BTU/s for thermal measurements but engineers think in horsepower. A 400 hp engine rejects about 280 BTU/s through its cooling system at full power (assuming 60% of fuel energy becomes waste heat). The conversion factor is easy to remember: multiply BTU/s by 1.4 to get hp.

The BTU originated as a water-heating energy unit, with several temperature-dependent variants. This converter uses the fixed International Table variant: 1 BTU(IT) = exactly 1,055.05585262 J. BTU-based energy and power units remain common in U.S. thermal engineering, equipment ratings and fuel-energy quantities. BTU alone measures energy; BTU per second, minute or hour measures power.

© 2026 TopConverters.com. All rights reserved.