ESU of current to Biot
ESU
Bi
Conversion History
| Conversion | Reuse | Delete |
|---|---|---|
1 ESU (ESU of current) → 0.00000000003335641 Bi (Biot) Just now · Rounding: Up to 8 significant figures | Recalculate this conversion using your current rounding settings. |
Quick Reference Table (ESU of current to Biot)
| ESU of current (ESU) | Biot (Bi) |
|---|---|
| 1 | 0.00000000003335641 |
| 10 | 0.0000000003335641 |
| 100 | 0.000000003335641 |
| 1,000,000 | 0.00003335641 |
| 1,000,000,000 | 0.03335641 |
| 3,000,000,000 | 0.10006923 |
Results rounded to a maximum of 8 significant figures
About ESU of current (ESU)
The electrostatic unit of current (ESU, also called the statampere) equals approximately 3.335640952×10⁻¹⁰ amperes under the traditional CGS-to-SI mapping used by this converter. It is the current unit of the CGS electrostatic system (CGS-ESU), in which Coulomb's law is written without a permittivity constant and electric charge is measured in statcoulombs (franklins). One statampere is the flow of one statcoulomb per second. The traditional mapping is 1 A = (c/10) statamperes, using the numerical speed of light c = 29,979,245,800 in cm/s, so 1 A maps to 2,997,924,580 statamperes. This is a conventional mapping, not a claim of an exact physical conversion to the post-2019 SI. The CGS-ESU system was used in early electrostatics and vacuum tube physics but is obsolete in applied engineering.
1 ESU of current ≈ 3.336×10⁻¹⁰ A — an extraordinarily small current. One ordinary ampere equals approximately 3×10⁹ ESU.
About Biot (Bi)
The biot (Bi) is the base unit of electric current in the centimeter-gram-second electromagnetic (CGS-EMU) system. Under the traditional pre-2019 CGS-to-SI mapping retained by this converter, one biot corresponds to 10 amperes. It is defined as the current in a pair of parallel conductors 1 cm apart that produces a force of 2 dynes per centimeter length — the CGS-EMU analogue of the former force-based SI ampere definition. The biot, EMU of current, and CGS e.m. unit are exactly the same current unit within CGS-EMU. Their 10 A relationship is a historical conversion convention rather than an exact physical conversion to the post-2019 SI, in which vacuum permeability is experimentally determined. The biot is essentially obsolete in modern practice, but it appears in older physics literature and classical electrodynamics textbooks alongside the dyne, gauss, and oersted.
Under the traditional mapping used here, 1 Bi corresponds to 10 A — roughly the draw of a domestic electric kettle. References to the biot appear primarily in historical or theoretical contexts, not modern instrumentation.
Etymology: Named after Jean-Baptiste Biot (1774–1862), French physicist who, with Félix Savart, established the Biot–Savart law describing the magnetic field generated by a steady electric current.
ESU of current – Frequently Asked Questions
Why is the ESU of current so absurdly small compared to an ampere?
The ESU system was designed to make Coulomb's electrostatic law simple (no constants), which means its charge unit (the statcoulomb) is tiny relative to the coulomb. Since current is charge per time, the statampere inherits that smallness. Under the traditional mapping used here, one ampere maps to 2,997,924,580 statamperes — the numerical speed of light in cm/s divided by 10. In the reverse direction, multiply the statampere value by 10/c, or divide by 2,997,924,580, to obtain amperes.
What is a statampere and is it the same as an ESU of current?
Yes. Statampere, ESU of current, CGS electrostatic current, franklin per second and Gaussian current share the same current scale. This converter uses the same traditional mapping for all five names: 1 A maps to 2,997,924,580 statamperes. "Statampere" is the named form; "ESU of current" is the descriptive form. The "stat-" prefix comes from "electrostatic," just as the "ab-" prefix in the EMU system comes from "absolute."
Did the 2019 SI redefinition change the statampere?
No. The statampere remains one statcoulomb per second in the CGS system. What changed was the SI ampere: in 2019 it was redefined by fixing the elementary charge, replacing its earlier force-based definition. Vacuum permeability and permittivity are consequently no longer exact SI constants, so physical conversions between CGS electrical units and modern SI involve measured values and uncertainty. This converter retains the pre-2019 mapping of 1 A to 2,997,924,580 statamperes for consistent reference conversions; it does not apply modern measured corrections.
What role did the ESU system play in the discovery that light is electromagnetic?
When Weber and Kohlrausch measured the ratio of ESU to EMU charge in 1856, they got a number suspiciously close to the speed of light — about 3×10¹⁰ cm/s. Maxwell realized this was no coincidence: it meant electromagnetic disturbances propagate at light speed, proving light itself is an electromagnetic wave. A unit conversion exercise led to one of the greatest discoveries in physics.
What practical problem did the ESU system solve for 19th-century telegraph engineers?
Telegraph cables behaved like long capacitors — charge stored along the line distorted signals over transatlantic distances. The ESU system, built around Coulomb's law, made capacitance calculations straightforward: no permittivity constants, just geometry and charge. William Thomson (Lord Kelvin) used ESU-based analysis to diagnose and fix signal distortion on the first transatlantic telegraph cables in the 1860s.
Why were electrostatic and electromagnetic measurements historically done in separate labs?
Electrostatic experiments (rubbing rods, Leyden jars, spark gaps) involved high voltages and tiny charges, while electromagnetic work (coils, galvanometers, telegraph lines) involved low voltages and large currents. The equipment, techniques, and even the physicists were different. Each community built units natural to their measurements — ESU for electrostatics, EMU for electromagnetics — and it took decades after Maxwell to unify them into one coherent SI framework.
Biot – Frequently Asked Questions
Why does this converter map one biot to 10 amperes?
The CGS-EMU system defines its base units using centimeters, grams, and seconds instead of meters, kilograms, and seconds. Under the former force-based SI ampere definition, converting the force between parallel currents made 1 Bi exactly 10 A. Since the 2019 SI redefinition, vacuum permeability is experimentally determined, so this converter retains 10 A as the stable traditional CGS-to-SI reference mapping rather than presenting it as an exact modern physical conversion.
Who was Jean-Baptiste Biot and why does he have a current unit?
Biot was a French physicist (1774–1862) who co-discovered the Biot–Savart law in 1820, describing how electric current generates a magnetic field in space. This was one of the foundational results linking electricity to magnetism. The CGS community honored him by naming their electromagnetic current unit after him.
Does anyone still use the biot in modern physics?
Essentially no. Even theorists who prefer CGS units typically use Gaussian units rather than pure CGS-EMU. The biot appears mainly in textbook conversion tables, historical physics papers, and graduate-level electrodynamics courses that teach multiple unit systems for pedagogical reasons.
How do I convert between biots and amperes?
Multiply biots by 10 to get amperes; divide amperes by 10 to get biots. A 30 A circuit carries 3 Bi; a 0.5 Bi current is 5 A. It is one of the simplest unit conversions in physics — just move the decimal point one place.
What is the Biot-Savart law and how does it relate to the biot unit?
The Biot-Savart law calculates the magnetic field produced by a small segment of current-carrying wire at any point in space. In CGS-EMU, it uses biots for current and gauss for the field. In SI it uses amperes and teslas. The law itself is fundamental — it is used to design MRI magnets, motors, and particle accelerators.